Climet Model CI-95A Microbial Air Sampler

In manufacture for over a decade, the CI-9xA Series of microbial samplers is the only model manufactured to meet or exceed all ISO 14698 standards and recommendations. Eliminate or mitigate deviation reports and investigations due to interval calibration out-of-tolerance conditions.

Specifications:
  • The CI-95A has a stainless steel enclosure, and our most popular model. It is an active air microbial sampler used in either sequential or continuous monitoring applications in aseptic areas.
  • The CI-95A is able to accommodate either industry standard 90 mm petri dishes, or RODAC plates; and is available in either 25 LPM, 1 CFM, or 100 LPM flow rates. The lower flow rates of 25 LPM or 1 CFM are recommended for continuous monitoring applications. Testing has confirmed that up to 3 hours (possibly longer) of continuous sampling with a custom agar fill of 40mL in a 90 mm petri dish is possible. Independent validation is recommended.
  • The Climet CI-9xA Series of microbial samplers is designed and built with the same ruggedness users have to come expect in Climet particle counters. It is the only pharmaceutical grade microbial air sampler that meets and exceeds all requirements AND recommendations of ISO 14698, as well as augmented by requirements in ISO 21501-4.
  • An expert in manufacturing industrial instrumentation, every new instrument design is drop and vibration tested ensuring end-users can expect up to a decade (and beyond) of reliable operation. This level of ruggedized testing is unique among other manufacturers, and ensures accidents don’t turn into capital appropriation requests or expensive repair bills.    

Climet Model CI-X70 Next Gen Series

Smallest and lightest Industrial and Pharmaceutical Grade Particle Counter with stainless steel enclosure, and 6-channels with a built-in printer, pdf reports, and the most advanced technology ensuring the highest level of accuracy and repeatability of measurement.

Drop and vibration tested for industrial use.

Specifications:
  • 6-channels: 0.3 µm to 10 µm, some models up to 25 µm
  • Flow Rate of 1 CFM, 50 LPM, 75 LPM, or 100 LPM
  • 21 CFR Part 11 Complaint
  • Industrial Use: 1m drop tested(14x up to 94 g’s)and a vibration tested (1 hour), then powered-up and passed calibration.
  • PDF (Portable Document Format) reports for ISO 14644:2015, GMP, and FS 209e with Sample Data Filtering (dates, etc.)
  • User Integrity Audit Trail
  • Display is a color LCD (cellphone-type) capacitive touch screen display (pinch to zoom, swipe to scroll)
  • Battery: Single lithium-ion for up to 6 hours of continuous operation (depending on model) – That’s a 100% duty cycle with a zero count filter installed.
  • New ultra-quiet / ultra-clean blower technology
  • Network time server synchronization – First on the market!
  • Sample Data Storage – Up to a million samples or more!
  • User IDs: 100, and factory expandable!
  • Location IDs: 100, and factory expandable!
  • Programs: 100, and factory expandable!

Climet Model CI-X5X Series

BioPharmaceutical grade, a 4-channel instrument in manufacture over a decade. The CI-x5x series offers traditional features, with unparalleled reputation for ruggedness and dependability.

Specifications:
  • The CI-x5x Series is a pharmaceutical grade 4-channel portable particle counters that comes in your choice of 1 CFM, 50 LPM, 75 LPM or 100 LPM flow rates.
  • Each model comes standard with an RS-232 serial interface, and is further differentiated by a variety of other data communication interfaces (Ethernet TCP/IP, Wi-Fi, and USB).
  • An internal thermal printer, no  plastics, VHP compatibility, fully integrated battery charger, internal sample data memory storage, integrated mass flow meter with automatic flow control, and other advanced features make Climet unique in the market.
  • Seamless stainless steel enclosure simplifies cleaning and sanitation.  A completely sealed front panel display prevents biocides, IPA, and other cleaning fluids from accidently leaking into the interior of the particle counter, thus eliminating the risk of short circuit or premature catastrophic damage to the sensor.
  • A lightweight instrument, it is the industry’s smallest and lightest full featured particle counter allowing easy transportability.
  • Climet is the only manufacture of particle counters that conducts emissions tests on every new factory model, and certifies emissions to ISO Class 3 or better. This provides an added level of assurance to end-users that their particle counters are not adding to the particle burden of their cleanroom.
  • High quality materials, an expert level of engineering acumen, and a mature DFM (Design For Manufacturability) virtually eliminate short-term and long-term calibration drift.

Climet Model CI-3100 Trident Series

BioPharmaceutical grade, a 2-channel (0.5 µm and 5.0 µm) particle counter with a 10,080 sample memory buffer, integrated light ring, and enhanced diagnostics. It is the first particle counter with a built-in vacuum pump offered with Power-Over-Ethernet (POE+). The CI-3100 TRIDENT Series is fully compliant with ISO 21501-4; PIC/S; FDA CGMP; EU GMP, Annex 1; ISO 14644-1/2:2015; 21 CFR Part 11, and others.

Specifications:
  • The CI-3100 TRIDENT Series primarily differs from the CI-3100 OPT, in that it provides sample data memory buffer for up to 10,080 samples (up to 1 week).
  • Trident Series is the first particle counter with a built-in vacuum pump that operates with Power-over-Ethernet (POE+). This technology injects power and ground onto standard network cabling, thus eliminating the need for wall power.  POE+ is a much sought after technology given safety protocols of some of the larger pharmaceutical and biotechnology producers. Alternative configurations also include Wi-Fi with wall power, or standard Ethernet TCP/IP with wall power.
  • One of the first recognizable differences is the user enabled/disabled Light Ring, which allows a 360 view of sample status.  The Trident particle counter also comes with output contact closures allowing simple and easy connectivity to an external light tower.
  • An optional Relative Humidity (RH) and Temperature probe is now available.
  • Sample data is provided end-users with a choice of either Ethernet Modbus, or CSV file upload; and the Trident model connects to existing network infrastructure.  The sample data output is 21 CFR Part 11 compliant, and can be easily uploaded into standard environmental monitoring systems including LIMS software. Wi-Fi synchronization and CheckSum insures data integrity and compliance with 21 CFR Part 11.