Model Number DS-11FX+

DeNovix DS-11 FX+ Spectrophotometers / Fluorometers

Specifications

Microvolume Mode

  • Spectral resolution is 1.5 nm
  • Minimum Sample Size is 0.5 µL
  • Pathlength is 0.5 mm (auto ranging to 0.02 mm)
  • Light Source: Pulsed Xenon flash lamp
  • Detector type is 2048 element CCD
  • Wavelength range is 190-840 nm
  • Wavelength accuracy is 0.5 nm
  • Wavelength precision is 0.14 nm
  • Spectral Resolution: 1.5 nm (FWHM at Hg 253.7 nm)
  • Absorbance Precision: 0.015 AU (1 cm) or 1%, whichever is greater
  • Absorbance Accuracy: 1.5% at 0.75 AU at 260 nm
  • Absorbance Range: 0.015 – 750 (1 cm equivalent)
  • Detection Limit: 0.04 mg/mL BSA; 0.75 ng/µL dsDNA
  • Maximum Concentration: 1125 mg/mL BSA; 37500 ng/µL dsDNA

Cuvette Mode

  • Beam height is 8.5 mm
  • Heating: 37-45 °C +/- 0.5 °C
  • Pathlength: 10, 5, 2, 1, 0.5, 0.2, 0.125 mm
  • Absorbance Range: 0.0008-1.5 AU (1 cm)
  • Detection Limit: 0.002 mg/mL BSA; 0.04 ng/µL dsDNA (1 cm)
  • Maximum Concentration: 75 ng/µL dsDNA (1 cm)

Fluorometer Mode

  • Light Sources: UV LED (~375 nm), Blue LED (~470 nm), Green LED (~525 nm), & Red LED (~635 nm)
  • Excitation Filters: UV: 361-389 nm, Blue: 442-497 nm, Green: 490-558 nm, Red: 613-662 nm
  • Emission Filters: 435-485 nm , 514-567 nm, 565-650 nm, & 665-740 nm
  • Detectors: Photodiode, detection range 300-1000 nm
  • Tube type is 0.5 mL Real Time thin-wall PCR tube (polypropylene)

Product Description

With the DS-11 FX series you can equip your lab for today’s quantification requirements and for future assay challenges. Combine the ease of use, wide dynamic range and contamination information of UV-Vis with the enhanced sensitivity and analyte-specific quantification of fluorescence for total sample quality control.

Founded in 1967, D.A.I. Scientific has provided solutions for the following companies:

Manufacturers Trust D.A.I. Scientific

D.A.I. is proud to represent an innovative and award-winning company like DeNovix.

DeNovix was formed in 2012 by a group of scientists and engineers with proven track records of manufacturing innovative products. They are driven by their passion to support and facilitate the advances made in today's scientific community.

The award-winning instruments by DeNovix are powered by their EasyApps® software. Pre-configured apps ensure that workflows are optimized and simple to use.

Each DeNovix instrument has the ability for onboard data storage. If you have to export your data, you can email, download to a USB or even print.

Product Features

SmartPath® Technology
The proprietary algorithms provide ultra-precise results by using real-time absorbance feed assessments to determine the optimum pathlength with which to measure the sample. This enables a best-in-class lower detection limit (0.75 ng/uL dsDNA, 0.60 ng/uL RNA or 0.04 mg/mL BSA) and the highest max detection (37500 ng/uL of dsDNA or 1125 mg/ml of BSA protein).
EasyApps® Software
DeNovix Spectrophotometers and Fluorometers are compact, stand-alone instruments with intuitive, EasyApps® for quantifying DNA, RNA and Protein. Pre-configured apps ensure that workflows are optimized while simple-to-use Custom Method apps enable researchers to quickly create and save methods. EasyApps® software also provides a multitude of choices for reviewing and exporting results. DeNovix SmartQC™ software alerts the user and advises on potential issues.
Always Calibrated
The DS-11 Series uses a high precision screw and optically encoded motor combination to make precise and reproducible pathlength adjustments. The system does not require regular calibration checks. There is no downtime or expense required for routine calibration like many other spectrophotometers.
Best in Class 1 uL Sensitivity and Highest Absorbance Capability
DS-11 Series Spectrophotometers set the industry standard for the lower detection limits of 0.5 -1.0 uL UV-Vis sample analysis. *Detect to 0.75 ng/uL dsDNA, 0.60 ng/uL RNA or 0.04 mg/mL BSA. The DS-11 can measure samples with absorbance values as high as 750 absorbance units (at a 1 cm equivalent path length). This translates into 1125 mg/ml of BSA protein or 37500 ng/uL of dsDNA
Fluorescence Freedom!
DeNovix fluorometers provide researchers with ease-of-use and flexibility like no other fluorometer available. *Four fluorescent channels allow scientists to utilize an expanded selection of fluorophores. Choose the assay you wish to work with, not the one dictated to you by a fluorometer manufacturer.

Resources

Screen Shot 2020-07-16 at 6.07.58 PM
Brochures
DeNovix DS-11
GET Brochures
Thumbnail DeNovix Fluorescence Measurement Best Practices
Whitepaper
DeNovix Fluorescence Measurement Best Practices
GET Whitepaper
Screen Shot 2020-07-20 at 3.14.26 PM
Whitepaper
Absorbance and Fluorescence Quantification
GET Whitepaper